Caution
-
Do not switch on chiller until proper setup completed
- Water in the tub filled to at least 50%
- Hoses are properly connected
- Do not tilt chiller as damage to compressor may occur
- Do not cover heat dissipation fan/vents
- Ensure chiller remains on the floor on a flat surface
Operation (video)
- Connect chiller inlet to SISU tub outlet (bottom connector); connect chiller outlet to SISU tub inlet (top connector)
- Fill tub to desired water height (at least half full)
- Switch on power
- Check and remove trapped air in the chiller system to improve water flow (video)
-
Set desired temperature
- Select SET on chiller
- Select UP/DOWN to desired temperature
- Select SET on chiller to lock in selection
Sanitation
-
Filter replacement (every 6-8 weeks or as needed)
- Remove metal cover for UV/Filter compartment
- Unscrew filter cup
- Replace the filter
- Screw filter cup back on
Drainage procedure, recommend water replacement every 2-4 weeks or more frequently dependent on usage (video):
-
Connect garden hose to quick connect fitting
- Screw male end of garden hose into female quick connector fitting
- Inside tub, plug finger into bottom opening (temporary stop water flow)
- Disconnect bottom chiller hose from SISU tub (where finger is)
- Connect garden hose with quick connect fitting onto SISU tub to drain water
- Remove finger (water should begin draining)
- When water level is below drainage hole, possible to drain remaining water on opposite side by removing cap
- Deep clean your tub with hot water/dish soap as needed
- Reconnect chiller to tub and refill water (at least half of tub) before turning on chiller
To use SISU as a cooler (for drinks or other food storage purposes)
- Drain/clean SISU tub
- Disconnect chiller hoses
- Thread male cap/plug to female quick connect fitting
- Put quick connecting fitting onto SISU tub
- Complete step 3 and 4 for inlet and outlet holes on SISU tub