Skip to content

    Chiller Manual and Cleaning

    Caution

    1. Do not switch on chiller until proper setup completed
      • Water in the tub filled to at least 50% 
      • Hoses are properly connected 
    2. Do not tilt chiller as damage to compressor may occur
    3. Do not cover heat dissipation fan/vents 
    4. Ensure chiller remains on the floor on a flat surface 

    Operation (video)

    1. Connect chiller inlet to SISU tub outlet (bottom connector); connect chiller outlet to SISU tub inlet (top connector)
    2. Fill tub to desired water height (at least half full)
    3. Switch on power
    4. Set desired temperature 
      • Select SET on chiller
      • Select UP/DOWN to desired temperature 
      • Select SET on chiller to lock in selection

    Sanitation

    1. Filter replacement (every 6-8 weeks or as needed)
      • Remove metal cover for UV/Filter compartment
      • Unscrew filter cup
      • Replace the filter 
      • Screw filter cup back on

     

        2. UV light replacement (if light is not on/broken, requires replacement)

      • Lightly detach UV light bottle from clip as shown below
      • Remove the black cap 
      • Replace UV light
      • Reattach black cap and reattach to clip

    Drainage procedure (recommend water replacement every 2-4 weeks or more frequently dependent on usage)

    1. Connect garden hose to quick connect fitting 
      • Screw male end of garden hose into female quick connector fitting
    2. Inside tub, plug finger into bottom opening (temporary stop water flow)
    3. Disconnect bottom chiller hose from SISU tub (where finger is)
    4. Connect garden hose with quick connect fitting onto SISU tub to drain water
    5. Remove finger (water should begin draining)
    6. When water level is below drainage hole, possible to drain remaining water on opposite side by removing cap
    7. Deep clean your tub with hot water/dish soap as needed
    8. Reconnect chiller to tub and refill water (at least half of tub) before turning on chiller

    To use SISU as a cooler (for drinks or other food storage purposes)

    1. Drain/clean SISU tub
    2. Disconnect chiller hoses 
    3. Thread male cap/plug to female quick connect fitting 
    4. Put quick connecting fitting onto SISU tub 
    5. Complete step 3 and 4 for inlet and outlet holes on SISU tub

    12 MONTH WARRANTY INCLUDED

    Every residential purchase includes a 12 month warranty

    SHOP NOW

    FINANCING AVAILABLE

    Flexible financing options through Affirm at checkout with low monthly payments.

    SHOP NOW